New! Sign up for our free email newsletter.
Science News
from research organizations

Simple bioreactor makes 'gut check' more practical

Device mimics intestines to show how invading bacteria cause disease

Date:
January 7, 2021
Source:
Rice University
Summary:
Researchers develop lab tool to mimic conditions in intestines, giving them a mechanical model for the real-time growth of bacterial infections.
Share:
FULL STORY

Rice University and Baylor College of Medicine researchers have found a way to mimic conditions in intestines, giving them a mechanical model for the real-time growth of bacterial infections.

In a new study, they demonstrate a lab tool that simplifies simulations of the human intestine, making it more practical to find treatments for diseases like infectious diarrhea.

The team led by bioengineer Jane Grande-Allen of Rice's Brown School of Engineering developed transparent millifluidic perfusion cassettes (mPCs) that are easy to fabricate and operate and compatible with common microscopic and biochemical analysis.

The cassettes allow even non-bioengineers to perform the kind of studies typically done with a 96-well petri dish, with the added benefit of fluid flow over seeded epithelial cells infected with bacteria. The cassettes also have micro-scale ports for input and output, allowing not only for fluid flow but also for sampling of the environment.

The study led by Grande-Allen, Rice's Isabel C. Cameron Professor of Bioengineering, and lead author and Rice and Baylor M.D./Ph.D. alumnus Reid Wilson, currently a resident at Oregon Health and Science University, appears in the Annals of Biomedical Engineering.

Replicating the complicated human gut is a challenge for researchers, said co-author Anthony Maresso, an associate professor of molecular virology and microbiology at Baylor. "Devices like these are often not user-friendly and practical for biologists like myself," he said. "This one was designed to be easy to use by scientists with less engineering know-how. The hope is it will lower barriers between engineers and medical researchers."

Grande-Allen said making a microfluidic system that doesn't leak can be technically challenging. "In this case, we needed to mimic the rate of fluid throughout the intestine that, especially compared to blood, is really slow," she said.

Molds of the devices, about the size of standard 96-well plates, were created with a 3D printer and used to form the clear polymer cassettes. The mPCs were seeded with human intestinal enteroids (HIEs), cultures that contain the major cell types native to the intestinal epithelium. When fluid containing bacteria flowed through, it formed a biofilm on the cells, a phenomenon not seen in static platforms.

Researchers can easily evaluate how well bacteria adhere to and infect the cells, both visually and by sampling through the ports on either end. Static plates allow bacteria to overgrow the cells and limit experiments to a few hours, but the slow flow through mPCs allows extended observation and more realistic results, Grande-Allen said.

Testing the device led the researchers to find the first direct evidence that aggregative adherence fimbriae, sticky appendages found on most infectious enteroaggregative Escherichia coli (EAEC), are necessary for the bacteria to form a biofilm.

"Our intention was to slowly flush the bacterial toxins to keep them from harming the cells," Grande-Allen said. "That allowed more cells to survive so we could watch the process of infection. We were completely surprised to see that it also dramatically changed the nature of the film that formed."

The devices also keep HIE cultures alive by replenishing oxygen and nutrients in the mPC chamber, allowing for better evaluation of realistic interactions between the cells and invading pathogens, Grande-Allen said.

She said mPCs will facilitate research on many such interactions. "This will allow the systematic examination of a lot of different combinations, good and bad, and how flow changes the dynamics of this environment," she said.


Story Source:

Materials provided by Rice University. Note: Content may be edited for style and length.


Journal Reference:

  1. Reid L. Wilson, Sarah A. Hewes, Anubama Rajan, Shih-Ching Lin, Carolyn Bomidi, Takanori Iida, Mary K. Estes, Anthony W. Maresso, K. Jane Grande-Allen. A Millifluidic Perfusion Cassette for Studying the Pathogenesis of Enteric Infections Using Ex-Vivo Organoids. Annals of Biomedical Engineering, 2021; DOI: 10.1007/s10439-020-02705-8

Cite This Page:

Rice University. "Simple bioreactor makes 'gut check' more practical." ScienceDaily. ScienceDaily, 7 January 2021. <www.sciencedaily.com/releases/2021/01/210107125301.htm>.
Rice University. (2021, January 7). Simple bioreactor makes 'gut check' more practical. ScienceDaily. Retrieved December 21, 2024 from www.sciencedaily.com/releases/2021/01/210107125301.htm
Rice University. "Simple bioreactor makes 'gut check' more practical." ScienceDaily. www.sciencedaily.com/releases/2021/01/210107125301.htm (accessed December 21, 2024).

Explore More

from ScienceDaily

RELATED STORIES