Tracking hydrogen movement using subatomic particles
Physicists detect local nuclear magnetic fields in a solid using negative muons
- Date:
- September 26, 2018
- Source:
- Osaka University
- Summary:
- Scientists have developed a technique using a beam of subatomic particles called muons to track hydrogen movement in the solid magnesium hydride for the first time. The negative muon beam provided spectra that showed the local nuclear magnetic fields of hydrogens in magnesium hydride. This technique expands our ability to investigate hydrogen transfer in solid materials, which should help to facilitate the development of hydrogen storage materials.
- Share:
A muon is an unstable subatomic particle similar to an electron but with much greater mass. The lifetime of a muon is only a couple of microseconds, but this is long compared with the lifetimes of many unstable subatomic particles. Because of their comparatively long lifetime, positive muons are often used to detect internal magnetic fields in solid materials. However, negative muons have seldom been used for this purpose because a large data set is required to obtain reliable results and experimental data collection times are normally limited. Recently, researchers developed a system that can count muon events at a much faster rate, allowing an experiment to be completed in a suitable time frame. Using this system, a Japanese collaboration has realized the long-standing goal of using negative muons to observe the local nuclear magnetic fields in a solid for the first time.
As explained in their article in Physical Review Letters, the team used magnesium hydride as the solid in their experiments. Magnesium hydride has a formula of MgH2 and is a potential candidate as a hydrogen storage material. Magnesium hydride was selected for study in experiments using the negative muon beam because muons initially captured on hydrogen are transferred quickly to magnesium, which allowed the transfer process of hydrogen to be investigated.
"The magnesium atoms exposed to the negative muon beam were effectively converted to sodium," says first author Jun Sugiyama at Toyota Central Research & Development Laboratories Inc. "The local magnetic field of the hydrogen atoms around these converted atoms was then able to be detected, which meant that we could track hydrogen diffusion."
The experiments used a high-intensity muon beam and highly integrated positron detector system to detect the local magnetic fields in the magnesium hydride sample. The obtained spectra were consistent with the magnesium atoms having a random magnetic field, agreeing with theoretical predictions. In particular, the results agreed with estimations from dipole field calculations, indicating that the nuclear magnetic fields of hydrogens in magnesium hydride were indeed observed.
"Our approach using negative muons to detect the local behavior of ions is attractive because it allows us to study the dynamics of light elements in a solid from the fixed point of the nucleus," says co-author Kazuhiko Ninomiya at Osaka University. "This approach is therefore complementary to nuclear magnetic resonance spectroscopy."
Using this negative muon-based technique, it is now possible to track the movement of hydrogen in a solid, which should aid the development of hydrogen storage materials.
Story Source:
Materials provided by Osaka University. Note: Content may be edited for style and length.
Journal Reference:
- Jun Sugiyama, Izumi Umegaki, Hiroshi Nozaki, Wataru Higemoto, Koji Hamada, Soshi Takeshita, Akihiro Koda, Koichiro Shimomura, Kazuhiko Ninomiya, M. Kenya Kubo. Nuclear Magnetic Field in Solids Detected with Negative-Muon Spin Rotation and Relaxation. Physical Review Letters, 2018; 121 (8) DOI: 10.1103/PhysRevLett.121.087202
Cite This Page: