New! Sign up for our free email newsletter.
Science News
from research organizations

The updated crystalline sponge method

Date:
March 9, 2016
Source:
International Union of Crystallography
Summary:
X-ray crystallographic analysis is one of the only methods that provides direct information on molecular structures at the atomic level. The method, however, has the intrinsic limitation that the target molecules must be crystalline, and high-quality single crystals must be prepared before measurement.
Share:
FULL STORY

X-ray crystallographic analysis is one of the only methods that provides direct information on molecular structures at the atomic level. The method, however, has the intrinsic limitation that the target molecules must be crystalline, and high-quality single crystals must be prepared before measurement. These limitations have often caused considerable problems for scientists in their determination of molecular structures. In 2013, a group of scientists reported a revolutionary new technique for single-crystal X-ray diffraction analysis that did not require the crystallisation of samples in the sample preparation [Inokuma et al. (2013), Nature, 495, 461-466].

This method, later coined the crystalline sponge method, uses crystals of porous metal complexes capable of absorbing guest compounds from solution in a common solvent. The guests are efficiently trapped and concentrated at several binding sites in the porous complexes, and the periodic array of the binding sites renders the absorbed guests oriented and observable by common X-ray diffraction studies.

However, the subsequent data quality of the trapped guest compound was not very high and the use of restraints and constraints based on chemical information was necessary to refine the guest structures. The need for this workaround was due purely to unoptimised experimental conditions and protocols. It soon became clear that to develop the crystalline sponge method from basic science into a reliable new technology that might innovate and support the molecular chemistry community, considerable effort was needed to improve the data quality. In addition, the crystallographic scope and limitations in the refinement of structures with large pores -- more commonly known as metal-organic framework (MOF) structures -- needed to be considered carefully. Over the last two years, therefore, the same group of researchers has made considerable advances in improving the data quality and uncovering the crystallographic scope and limitations for the refinement of guest structures obtained using the crystalline sponge method.

These researchers anticipate renewed interest in the technique and hope further experimentation by the community will improve the quality and value of the protocol.


Story Source:

Materials provided by International Union of Crystallography. Note: Content may be edited for style and length.


Journal Reference:

  1. Manabu Hoshino, Anupam Khutia, Hongzhu Xing, Yasuhide Inokuma, Makoto Fujita. The crystalline sponge method updated. IUCrJ, 2016; 3 (2): 139 DOI: 10.1107/S2052252515024379

Cite This Page:

International Union of Crystallography. "The updated crystalline sponge method." ScienceDaily. ScienceDaily, 9 March 2016. <www.sciencedaily.com/releases/2016/03/160309124751.htm>.
International Union of Crystallography. (2016, March 9). The updated crystalline sponge method. ScienceDaily. Retrieved November 21, 2024 from www.sciencedaily.com/releases/2016/03/160309124751.htm
International Union of Crystallography. "The updated crystalline sponge method." ScienceDaily. www.sciencedaily.com/releases/2016/03/160309124751.htm (accessed November 21, 2024).

Explore More

from ScienceDaily

RELATED STORIES