New! Sign up for our free email newsletter.
Science News
from research organizations

A new tool for 3-D measurement of the aorta may identify fatal heart conditions earlier

The technique has potential to change the way aortic aneurysm is monitored.

Date:
February 16, 2022
Source:
Michigan Medicine - University of Michigan
Summary:
Researchers have developed a novel method of measuring growth in the aorta that may help clinicians to identify potentially fatal heart conditions earlier. The technique, called vascular deformation mapping, measures changes in the thoracic aorta by using high-resolution CT imaging to calculate three-dimensional changes in the aortic wall. In the study, VDM significantly outperformed the standard manual rating methods performed by experts.
Share:
FULL STORY

Researchers at Michigan Medicine have found a novel method of measuring growth in the body's largest artery that may help clinicians to identify potentially fatal heart conditions earlier.

The technique, called vascular deformation mapping, measures changes in the thoracic aorta, which carries blood from the heart to the rest of the body. This new technique uses high-resolution CT imaging to calculate three-dimensional changes in the aortic wall in a manner that significantly outperforms the standard manual rating methods performed by experts, according to results published in Radiology and Medical Physics.

"The technique used in this algorithm has been around for a while, but no one has ever used it to see three-dimensional growth of an aneurysm of the thoracic aorta," said Nicholas Burris, M.D., corresponding author of the papers, assistant professor of radiology and director of aortic imaging at Michigan Medicine. "This is a promising step towards having technology that pushes the accuracy of measurement past what human raters can achieve, allowing clinicians to have the best possible picture of a patient's condition."

Thoracic aortic aneurysm occurs when the largest part of the aorta becomes weakened and grows, or dilates, increasing its risk of a potentially fatal rupture or dissection. For approximately 3% of adult patients over 50 years old with this largely asymptomatic condition, physicians recommend they undergo regular testing, often with CT scans, to measure aortic growth and determine if surgical repair is needed.

Currently, the standard practice to measure growth is done with human "raters" who line up two images and draw a line at two points to find the change. Burris says this process is prone to error, and, in many cases, doctors can't confidently tell if the thoracic aorta is growing, creating uncertainty regarding the best treatments and follow-up plan.

"The challenge we're faced with clinically is that a typical aneurysm in the aorta is going to grow only a fraction of a millimeter every year, and the process of manually drawing diameters that precise is very hard to reproduce," he said. "You have a lot of variability in standard measurements relative to a very small amount of actual aneurysm growth. Basically, you rarely end up getting a confident assessment of growth, which can make it difficult to know what the patient's actual risk is and how closely they need to be followed with repeat CT scans."

The vascular deformation mapping technique developed by Burris' team relies on an image analysis technique known as image registration, which, essentially, aligns the anatomy shown in multiple CT scans by taking any pixel on the first scan and relating its exact position to the pixel on the second scan. When they are all aligned, a three-dimensional color map of the aorta shows how much and where the thoracic aorta has grown.

For these studies, researchers used scans from nearly 50 aortic aneurysm patients and 75 reference models with variable growth of the aortic wall. They tested the automated program against two expert manual raters and found the vascular deformation mapping outperformed the humans with higher accuracy and lower variability in the growth measurements. Vascular deformation mapping achieved an accuracy of less than 1 millimeter in all cases when even the most experienced human analysts had measurements with errors of up to 3 millimeters.

"Recent advances in artificial intelligence have generated a lot of interest in AI in relation to automating radiology tasks," said Charles Hatt, Ph.D., co-author of the paper and adjunct research assistant professor of radiology at Michigan Medicine. "It turns out that replacing human radiologists is not a simple task, and a more realistic goal for AI is to speed-up workflows and assist radiologists in making object, quantitative measurements that are otherwise cumbersome to perform and inherently subjective. In this regard, vascular deformation mapping is a perfect, real-world example of how AI and quantitative imaging can improve clinical care by empowering clinicians rather than attempting to replace them."

While these reports show vascular deformation mapping may be more useful than human rating to inform whether surgery is necessary on an aortic aneurysm, researchers say the approach must be studied further in large groups of patients in a clinic. Fortunately, Burris says, the vascular deformation mapping technique can be performed on routine CT scans of the aorta, making performing larger research studies easier.

"This is a totally new way of looking at aortic aneurysm growth," he said. "As this develops, there is a possibility to deploy this across a larger spectrum of diseases, such as abdominal aortic aneurysm. Moving from the current one-dimensional measurements to a three-dimensional approach lets us see patterns of aneurysm growth in a way never before possible and allows us to ask many new questions and learn how a highly-accurate tracking tool like this can be used to ultimately improve care for patients."

The first paper's additional authors include Zhangxing Bian, M.S., Michigan Medicine Department of Radiology, Jeffrey Dominic, M.S., Michigan Medicine Department of Radiology, Jianyang Zhong, M.S., Michigan Medicine Department of Radiology, Ignas B. Houben, M.D., Michigan Medicine Department of Cardiac Surgery, Theodorus M.J. van Bakel, M.D., Michigan Medicine Department of Cardiac Surgery, Himanshu J. Patel, M.D., Michigan Medicine Department of Cardiac Surgery, Brian Ross, Ph.D., Michigan Medicine Center for Molecular Imaging, and Gary Christiansen, Ph.D., University of Iowa Department of Electrical and Computer Engineering

The second paper's additional author's include Zhangxing Bian, M.S., Michigan Medicine Department of Radiology, Jianyang Zhong, M.S., Michigan Medicine Department of Radiology Jeffrey Dominic, M.S., Michigan Medicine Department of Radiology, Gary Christiansen, Ph.D., University of Iowa Department of Electrical and Computer Engineering.

Imbio, LLC, has exclusive licensing rights to the intellectual property the vascular deformation technique described in this post. Hatt is an Imbio employee with stock in Imbio. Burris is a co-inventor of VDM with royalties related to intellectual property of VDM technology.

Burris supported by Radiological Society of North America Research Scholar Grant (RSCH1801). Burris and Hatt supported by the National Institutes of Health (R44 HL145953).


Story Source:

Materials provided by Michigan Medicine - University of Michigan. Original written by Noah Fromson. Note: Content may be edited for style and length.


Journal References:

  1. Zhangxing Bian, Jiayang Zhong, Jeffrey Dominic, Gary E. Christensen, Charles R. Hatt, Nicholas S. Burris. Validation of a robust method for quantification of three‐dimensional growth of the thoracic aorta using deformable image registration. Medical Physics, 2022; DOI: 10.1002/mp.15496
  2. Nicholas S. Burris, Zhangxing Bian, Jeffrey Dominic, Jianyang Zhong, Ignas B. Houben, Theodorus M. J. van Bakel, Himanshu J. Patel, Brian D. Ross, Gary E. Christensen, Charles R. Hatt. Vascular Deformation Mapping for CT Surveillance of Thoracic Aortic Aneurysm Growth. Radiology, 2022; 302 (1): 218 DOI: 10.1148/radiol.2021210658

Cite This Page:

Michigan Medicine - University of Michigan. "A new tool for 3-D measurement of the aorta may identify fatal heart conditions earlier." ScienceDaily. ScienceDaily, 16 February 2022. <www.sciencedaily.com/releases/2022/02/220216112236.htm>.
Michigan Medicine - University of Michigan. (2022, February 16). A new tool for 3-D measurement of the aorta may identify fatal heart conditions earlier. ScienceDaily. Retrieved December 21, 2024 from www.sciencedaily.com/releases/2022/02/220216112236.htm
Michigan Medicine - University of Michigan. "A new tool for 3-D measurement of the aorta may identify fatal heart conditions earlier." ScienceDaily. www.sciencedaily.com/releases/2022/02/220216112236.htm (accessed December 21, 2024).

Explore More

from ScienceDaily

RELATED STORIES